How to Bypass Control Board on Pellet Stove

Bypassing the control board can be a useful way to reduce the cost of maintaining your pellet stove. By bypassing the control board, you can eliminate the need for costly repairs and prolong the lifespan of your appliance. It may also help reduce energy costs by controlling how much heat is produced in your home. 

With fewer components to maintain and fewer energy costs, bypassing the control board can be an economical and efficient solution. When bypassing the control board, it’s important to take safety precautions. Always ensure that all your power sources are off before bypassing the control board. 

Additionally, you should ensure you’re familiar with the wiring diagrams, as incorrect wiring may lead to a fire hazard. If your pellet stove malfunctions and the control board is unresponsive, you may be able to bypass the control board and still use your stove. Please note that this is a temporary fix and should only be used as a last resort. In this blog post, You will learn in detail how to bypass control board on pellet stove. 

How to Bypass Control Board on Pellet Stove

Step by Step Processes for How to Bypass Control Board on Pellet Stove

Step 1:  Locate the Control Board

First, locate the control board inside your pellet stove. This should be near where the power cord is connected to your stove.  It is usually a gray box and may have red buttons on it. Next, disconnect all of the wires that are connected to the control board. Be sure to note where each wire was connected so you can reconnect them later.

Step 2: Place the Bypass Connector 

Now place the bypass connector across both the positive and negative terminals on the board. This will serve as a bridge to bypass the control board entirely. Once you have placed the bypass connector, use electrical tape or a wire nut to secure it in place. Make sure it is tightly connected and won’t lose over time.

Step 3: Reconnect the Wires

Now that the bypass connector is in place, it’s time to reconnect all of the wires you previously removed from the control board. Make sure that each wire is reconnected to its original terminal.

Reconnect All of the Wires

Step 4: Test the Pellet Stove

Now that you have bypassed the control board, it’s time to test your pellet stove. Plug it in and turn it on. If everything is connected correctly, the stove should turn on without any issues. Once you have tested the pellet stove, inspecting the connection points where you placed the bypass connector is a good idea. Make sure that everything is secure and that there are no exposed wires.

Step 5: Switch Between Bypass and Control Board Settings

If you need to be able to switch between using the control board and bypassing it, then simply unplug the bypass connector and plug the control board back in. This will allow you to switch between the two settings at any time.

Step 6: Test Pellet Stove Again

Once you have switched between the two settings, it’s a good idea to test your pellet stove again. This will ensure that everything is connected correctly and working properly.

Test Your Pellet Stove

You Can Check It Out To Turn off Sensor on Moen Faucet

Tips for How to Bypass Control Board on Pellet Stove 

  1. Always ensure the pellet stove is unplugged before bypassing the control board.
  2. Check the owner’s manual for instructions for bypassing the control board on your model pellet stove.
  3. Ensure all electrical connections are properly tightened and in good condition to avoid potential hazards.
  4. Always use the appropriate tools when connecting or disconnecting wires and wear protective gloves and eye protection.
  5. Test all wiring for continuity before bypassing the control board on the pellet stove.
  6. Make sure to double-check your work by performing a voltage test before operating the pellet stove.
  7. If you are unsure of your ability to bypass the control board, it is best to contact a qualified and experienced technician for assistance.
  8. Always be sure to follow safety instructions when working with electricity or electronic components.
  9. Be aware that bypassing the control board may void any warranties attached to the pellet stove.

By following these safety tips, you can safely bypass a control board on your pellet stove without harming yourself or your equipment.

Test All Wiring for Continuity

How Long Does It Take to Bypass the Control Board on a Pellet Stove?

Bypassing the control board of a pellet stove can be done relatively quickly and easily. While it depends on your familiarity with the procedure, most people can complete the task in 15-20 minutes.

The first step is to find and unplug the plug from its socket that connects the pellet stove’s control board to the wall outlet. After this is done, the control board can be removed and set aside. The next step is to find the bypass wires on the pellet stove’s auger motor and run them across the center of the control board cavity. This will establish a direct connection between the two elements, allowing for uninterrupted operation without using the board.

Once this is done, the new connections can be secured with electrical tape or another suitable insulating material. Finally, the plug should be re-connected, and the pellet stove should be checked to see if it works properly. Bypassing the control board of a pellet stove can help extend its service life and reduce the need for costly and time-consuming repairs.

Are There Any Risks Associated With Bypassing the Control Board on a Pellet Stove?

Bypassing the control board on a pellet stove can pose many risks. When bypassing the control board, it is important to understand that it was put in place for safety reasons. Bypassing this system means losing all of its safety features and should only be done after consulting with a certified technician or manufacturer. 

It is important to note that bypassing the control board could also cause problems with how the stove operates, such as not shutting off when it should, leading to a potential fire hazard. Additionally, some stoves require electricity even when they are off, so bypassing the control board could lead to an overload of electricity and potentially create a fire. 

In short, bypassing the control board on a pellet stove can be dangerous and should only be done after consulting with a certified professional or stove manufacturer. It is important to understand all the potential risks involved before proceeding.

Bypassing the Control Board on a Pellet Stove

How Often Should You Check That Your Pellet Stove is Working Properly After It Has Been Bypassed?

After bypassing the control board on your pellet stove, it is important to check that it is regularly working properly. Generally, you should check the stove before and after each use. This will help identify any issues with the bypassed control board before they get out of hand.

It is also important to inspect other parts of the pellet stove, such as the hopper and exhaust pipe, for signs of damage or wear. If any parts are found to be damaged or need repair, they should be replaced or repaired before using the stove again. Additionally, it is important to regularly clean the burn pot and ashpan to prevent build-up, which could cause a fire hazard.

Is It Necessary to Call Any Professional to Bypass Control Board on Pellet Stove?

The truth is, it depends on the damage’s severity and how comfortable you feel performing the repairs yourself. If your stove is relatively new and the damage is minor, then you may be able to bypass the control board on your own. However, if the damage is more severe or your stove is older, it’s probably best to call a professional. 

Bypassing a control board can be a tricky repair, so it’s important to make sure that you know what you’re doing before attempting it. In most cases, it’s best to err on the side of caution and call a professional. They will be able to assess the situation and make sure that the repair is performed correctly, preventing further damage to your stove.

How Much Will It Cost if You Hire a Professional? 

Hiring a professional to bypass your control board on a pellet stove will cost you anywhere between $75 and $200 depending on the technician’s experience, the parts needed, and how much time it will take. You should shop around for competitive prices if you’re considering hiring a professional. Additionally, some technicians may offer discounts if you’re willing to purchase the parts from them.

If you decide to hire a professional, make sure that you ask for references and proof of insurance. It is recommended that you inquire about their experience with pellet stoves and any certifications they have or organizations they are members of. You may also want to ask the technician if they are familiar with the brand and model of your pellet stove.

Conclusion

Bypassing the control board on a pellet stove can be complicated and risky, but if done correctly, it can help restore your old or malfunctioning pellet stove to working order. Various strategies for bypassing the control board range from simply replacing it with a new one to using jumper wires in certain configurations. 

Regardless of your approach, ensure that you understand the instructions and use appropriate safety measures. With a little bit of know-how and the right tools, anyone can bypass the control board on their pellet stove quickly and easily. I hope this article has been beneficial for learning how to bypass control board on pellet stove. Make Sure the precautionary measures are followed chronologically.

Leave a Comment